Back to Training Center
Lesson 02
Manual Point Pair alignment
1:06Alignment
When Auto Align cannot find the pose, place the scan by hand: pick three matching features on the CAD and on the scan, apply the point-pair alignment, then refine it with fine ICP and save the aligned scan.