Back to Training Center
Lesson 02

Manual Point Pair alignment

1:06
Alignment

When Auto Align cannot find the pose, place the scan by hand: pick three matching features on the CAD and on the scan, apply the point-pair alignment, then refine it with fine ICP and save the aligned scan.